Row spacing

Site

Units

Rack

Panels
°
°

Rows

Winter rule

No row shades the next between these hours (solar time) on the shortest day.

Rows

Row pitch, front to front
Energy per acre

Section

Closer rows

Energy per kW of panels: the shading cost of closer rows.

Energy per acre of rows: more panels on the same land.

Lower tilt

Rows at the winter rule for each tilt

Energy per kW of panels.

Energy per acre of rows.

History

Notes

Rows of panels on the ground or a flat roof cast shadows on the rows behind them, most of all on winter mornings and afternoons when the sun is low. Spacing them farther apart avoids that, but uses more land. This page finds the spacing for no shade through the middle of the shortest day, and shows what closer rows or a lower tilt do to the energy from each panel and from each acre.

SolarPlan is a free, independent project, developed by enginerds from the University of Southern California and the University of Pennsylvania.

The winter rule

The common rule spaces rows so that none shades the next from 9 am to 3 pm solar time on the winter solstice. What sets the spacing is the sun’s angle measured across the rows (its profile angle), which is lowest at the ends of that window. A row of slant length L at tilt β, with the sun at profile angle ψ, casts a shadow reaching L·sin β / tan ψ behind its top edge; the rows sit that far apart plus their own depth, L·cos β. The ground coverage ratio is the slant length over the pitch.

Rows facing south, clear of shade from 9 am to 3 pm on December 21. The pitch is for racks two 1.72 m panels high, in portrait.
CityLatitudeSun across rowsCoverage at 20°at 25°at 30°Pitch at 25°
Seattle47.6°11°0.370.320.2935.2 ft
San Francisco37.8°21°0.540.490.4623.0 ft
Los Angeles34.1°24°0.590.540.5120.8 ft
Phoenix33.4°25°0.600.550.5220.6 ft
Denver39.7°19°0.510.460.4324.4 ft
Dallas32.8°26°0.610.560.5320.2 ft
Minneapolis45.0°14°0.420.380.3430.3 ft
Chicago41.9°17°0.480.430.3926.4 ft
Atlanta33.7°25°0.590.550.5120.7 ft
Miami25.8°33°0.680.640.6117.8 ft
New York40.7°18°0.500.450.4125.2 ft
Boston42.4°16°0.470.420.3926.9 ft

Closer rows and lower tilts

Rows closer than the winter rule lose some energy to shading, mostly in winter, and some sky light at every hour, but put more panels on each acre. Where land is the limit, closer rows usually win; where panels are the limit, the winter rule or wider is better. A lower tilt does both: each panel gives up some energy, but its shorter shadow lets the rows close up. Large US plants typically use coverage ratios of 0.40 to 0.50 for fixed tilt and 0.25 to 0.40 for single-axis trackers (Berkeley Lab, 2022).

How it works

Energy is computed hour by hour over a typical year with the model PVWatts version 8 uses (National Laboratory of the Rockies), including its row-shading model: the shadow of each row on the next, with the strings wired along the rows, and the sky and ground light the rows block. The field stands for a large array of 20 rows. Energy per acre counts only the rows: modules at their rated efficiency times the coverage ratio. Roads between blocks, inverter pads, fences and setbacks add land. For comparison, Berkeley Lab measured US plants built through 2019 at a median 0.35 MW DC per acre of array area for fixed tilt and 0.24 for trackers. Level ground is assumed: rows on a slope facing the sun can sit closer, and on a slope facing away need more room.

Privacy

SolarPlan counts visits with Vercel Web Analytics, without tracking cookies: it tells visits apart by a hash of the request that is discarded after 24 hours, and records the page, the site that linked to it, a rough location, and the kind of device and browser. Vercel Speed Insights records how fast pages load. Links carry your place and settings, but only the page’s path is reported. Your history and last settings stay in your browser.

Sources